Home >> BMW >> 2009 >> 550i Automatic >> Repair and Diagnosis >> Body & Frame >> Windows >> General Electrical System - Repair >> Plug Connection, Terminal, Power Distribution Box >> 61 13... Installing comb connector for retrofitting/repairs >> Installation in wet area (engine compartment, wheel arch)
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Installation in wet area (engine compartment, wheel arch)

Apply sealing compound on both sides and press into contacts (1).

Fit heat-shrink tubing and heat up with hot air blower (2) (approx. 250 °C).

NOTE: Ensure that comb connector has sufficient contact surface on attachment point.

Do not heat-shrink tubing on edges of comb connector too strongly, risk of cracking.

Fig 1: Identifying Sealing Compound Properly Applied And Dried On Comb Connector
G04753283Courtesy of BMW OF NORTH AMERICA, INC.

Allow heat-shrink tubing to cool down until hand-warm. Then press sealing material again into contacts and onto edges of comb connector.

If necessary, carefully heat-shrink tubing again.