86 10... Adjusting spring force accumulator
The spring force accumulator requires no maintenance and generally does not need to be readjusted.
Adjustment dimension, spring force accumulator: distance between end of support tube - internal washer (1) is 90 mm.
To tension spring force accumulator: turn nut (2) located in support tube (1) clockwise.
To relieve tension on spring force accumulator: turn nut (2) located in support tube (1) counterclockwise.