Home >> BMW >> 2013 >> M3 2D Convertible, Standard Trans >> Repair and Diagnosis (Single Page) >> General Information >> OEM General Information >> Functional Description -- M3 Convertible >> Body Electrical - Functional Description >> Protective Functions For The Power Windows >> Temperature protection (all series)
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Temperature protection (all series)

The temperature protection (thermal overload protection) is activated whenever the window is opened and closed 4 to 10 times in quick succession.

The window can then only be closed and is then disabled for 8 to 10 minutes.

After this cooling-down period, the power window drive can again be used normally.

The precise behavior (maximum number of operations and switch-off time) depends on the vehicle voltage and the programmed control unit software.