Leak Detection In The Refrigerant Circuit, Air Conditioning With Mechanical A/C Compressor
The following sequence of checks is recommended to detect leaks in the refrigerant circuit:
- Checking the refrigerant circuit with leak detection spray
- Checking the A/C condenser
- Checking the evaporator
If there is good reason to suspect that a specific component is faulty, it is permitted to deviate from the sequence of checks at Points 1, 2 and 3.
- Only if no leak has been found in the refrigerant circuit by checks 1, 2 and 3, can menu item 4 be performed.