Home >> BMW >> 2015 >> M5 Standard Trans >> Repair and Diagnosis (Single Page) >> General Information >> OEM General Information >> Functional Description - F10 - Charging System, Anti-Theft System, Body Electrical System >> Charging System - Functional Description >> Lithium ion battery >> Starting capability
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Starting capability

The starting capability of the lithium ion battery is calculated by power management and displayed. The state of charge does not drop below 20 % in the process due to reasons of safety.

In temperatures above 10 °C an engine start can actually be successful in case of low states of charge as well. The following is an example of a new lithium ion battery at 25 °C.

Fig 1: AGM Battery Voltage Graph
G09909986Courtesy of BMW OF NORTH AMERICA, INC.
Item Explanation
1 Battery voltage in volts
2 Starting capability in percent
3 Battery voltage curve
4 State of charge curve