61 13... Crimping Micro Power Quadlock contacts (MPQ)

Special tools required: 

To crimp MPQ contacts, use hand pliers 61 4 321 (1) in conjunction with crimping head 61 4 325 (2) from crimping set 61 4 320 .

NOTE: Hand pliers (1) open automatically until limit position when handles are pressed together.
Fig 1: Crimping MPQ Contacts Using Hand Pliers (61 4 321)
G04727513Courtesy of BMW OF NORTH AMERICA, INC.

Open hand pliers (1).

NOTE: Place contact (2) with utmost care in designated nest (observe line cross-section) in crimping head (3). Make sure it is exactly positioned.

Place MPQ contact (2) in crimping head (3).

Close hand pliers (1) one notch.

Fig 2: Identifying Hand Pliers With Crimping Head And MPQ Contact
G04727514Courtesy of BMW OF NORTH AMERICA, INC.
NOTE: Follow procedure for CUTTING AND STRIPPING INSULATION  from cables.

Insert stripped cable (2).

Close hand pliers (1) fully.

Open hand pliers (1) and remove cable (2).