61 13... Control unit plugs, 25-, 35-, 55-, 83-, 88-pin
Special tools required:
- 61 0 312
- 61 0 314
- 61 0 315
- 61 0 323
Release screws (1).
Lever out pin sensor (2) with gasket (3) in direction of arrow.
Remove gasket (3).
Pull out housing lock (4) in direction of arrow and unlock.
Press down retaining hook (5) of corresponding contact and pull out cable with contact.
Special tool 61 0 312 (61 1 134) for mini flat spring contacts.
Special tool 61 0 314 (61 1 135) for mini flat spring contacts.
Special tool 61 0 315 (61 1 151) for double flat spring contacts (dual retaining hooks).
Special tool 61 0 323 (61 1 152) for double flat spring contacts (special retaining hook).