SYSTEM PERFORMANCE CHART (AT 70°F/21°C AMBIENT AIR TEMPERATURE)

Application Specification
Ambient Air in Degrees °F/°C 70°F/21°C
Hi Side Pressure (1) 149 PSI
Pressure Plus and/or Minus 20 PSI (+/- 140 kPa) 1025 kPa
Lo Side Pressure (1) 25 PSI
Pressure Plus and/or Minus 2 PSI (+/- 8 kPa) 170 kPa
Center A/C Outlet Temperature (2) (+/- 2°F (1°C)) 50°F (10°C)
(1) Pressure reading taken just before Compressor Clutch releases.
(2) Outlet temperature will be higher on humid days.
SYSTEM PERFORMANCE CHART (AT 80°F/27°C AMBIENT AIR TEMPERATURE)

Application Specification
Ambient Air in Degrees °F/°C 80°F/27°C
Hi Side Pressure (1) 178 PSI
Pressure Plus and/or Minus 20 PSI (+/- 140 kPa) 1225 kPa
Lo Side Pressure (1) 27 PSI
Pressure Plus and/or Minus 2 PSI (+/- 8 kPa) 185 kPa
Center A/C Outlet Temperature (2) (+/- 2°F (1°C)) 52°F (11°C)
(1) Pressure reading taken just before Compressor Clutch releases.
(2) Outlet temperature will be higher on humid days.
SYSTEM PERFORMANCE CHART (AT 90°F/32°C AMBIENT AIR TEMPERATURE)

Application Specification
Ambient Air in Degrees °F/°C 90°F/32°C
Hi Side Pressure (1) 214 PSI
Pressure Plus and/or Minus 20 PSI (+/- 140 kPa) 1475 kPa
Lo Side Pressure (1) 29 PSI
Pressure Plus and/or Minus 2 PSI (+/- 8 kPa) 200 kPa
Center A/C Outlet Temperature (2) (+/- 2°F (1°C)) 54°F (12°C)
(1) Pressure reading taken just before Compressor Clutch releases.
(2) Outlet temperature will be higher on humid days.
SYSTEM PERFORMANCE CHART (AT 100°F/38°C AMBIENT AIR TEMPERATURE)

Application Specification
Ambient Air in Degrees °F/°C 100°F/38°C
Hi Side Pressure (1) 272 PSI
Pressure Plus and/or Minus 20 PSI (+/- 140 kPa) 1875 kPa
Lo Side Pressure (1) 33 PSI
Pressure Plus and/or Minus 2 PSI (+/- 8 kPa) 230 kPa
Center A/C Outlet Temperature (2) (+/- 2°F (1°C)) 56°F (13°C)
(1) Pressure reading taken just before Compressor Clutch releases.
(2) Outlet temperature will be higher on humid days.
FREON PRESSURE/TEMPERATURE RELATIONSHIP CHART - LOW SIDE (1)

Pressure (PSI) Tempurature °F (°C)
50 53 (12)
52 55 (13)
54 57 (14)
56 59 (15)
58 60 (15.5)
60 62 (16.6)
62 64 (18)
64 65 (18.5)
66 67 (19.5)
68 68 (20)
70 70 (21)
72 72 (22)
74 74 (23.5)
76 75 (24)
78 76 (24.5)
80 77 (25)
82 79 (26)
85 81 (27)
88 83 (28.5)
90 84 (29)
92 85 (29.5)
95 87 (30.5)
98 89 (31.5)
100 90 (32.5)
102 91 (33)
105 93 (34)
108 95 (35)
110 96 (35.5)
112 97 (36)
115 99 (37)
118 101 (38.5)
120 102 (39)
125 104 (40)
130 107 (42)
135 109 (43)
140 112 (44.5)
(1) A/C Low Side BD 28 check made after 5 minutes with engine "OFF". A given pressure should correspond to a temperature reading plus and/or minus 6°F of the specified value.