K33 HVAC Control Module X3 Connector End View

WARNING: This page is about a different car, the 2011 Buick Regal. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: K33 HVAC Control Module X3 Connector End View
GM1715223Courtesy of GENERAL MOTORS CORP.
K33 HVAC Control Module X3

Pin Wire Circuit Function
1 0.35 GY/D-GN 516 Upper Left Air Temperature Sensor Signal
2 0.35 YE 3165 Mode Door Stepper Motor Control (1)
3 0.35 WH/RD 3166 Mode Door Stepper Motor Control (2)
4 0.35 GY/BN 3167 Mode Door Stepper Motor Control (3)
5 0.35 D-GN/WH 3168 Mode Door Stepper Motor Control (4)
6-8 - - Not Used
9 0.35 BK 407 Sensor Low Reference
10 - - Not Used
11 0.35 D-GN 3169 Temp Door Stepper Motor Control (1)
12 0.35 WH/RD 3170 Temp Door Stepper Motor Control (2)
13 0.35 GY/RD 3171 Temp Door Stepper Motor Control (3)
14 0.35 RD/BK 3172 Temp Door Stepper Motor Control (4)
15 0.75 OG 7572 HVAC Motor Supply Voltage
16 0.35 GY 3173 Air Inlet Door Stepper Motor Control (1)
17 0.35 D-BU/WH 3174 Air Inlet Door Stepper Motor Control (2)
18 0.35 BN/D-GN 3175 Air Inlet Door Stepper Motor Control (3)
19 0.35 RD/GN 3176 Air Inlet Door Stepper Motor Control (4)
20 0.35 BK/GY 6137 EVAP Core Temperature Sensor Signal
Connector Part Information 
  • Harness Type: HVAC
  • OEM Connector: 15126711
  • Service Connector: 15126711
  • Description: 20-Way F 64 Series (BK)
Terminal Part Information 
  • Terminated Lead: Service by Harness - See Part Catalog
  • Release Tool: Not Available
  • Diagnostic Test Probe: Pending
  • Terminal/Tray: Service by Harness - See Part Catalog
  • Core/Insulation Crimp: Not Available