Circuit/System Testing
WARNING: This page is about a different car, the 2012 Buick Verano. However, it is still accessible from the selected car via links, so may be relevant.
- Ignition OFF, disconnect the X2 harness connector at the K8 blower motor control module. It may take up to 2 minutes for all vehicle systems to power down.
- Test for less than 5 Ω between the ground circuit terminal 5 and ground.
- If 5 Ω or greater
- Ignition OFF.
- Test for less than 2 Ω in the ground circuit end to end.
- If 2 Ω or greater, repair the open/high resistance in the circuit.
- If less than 2 Ω, repair the open/high resistance in the ground connection.
- If less than 5 Ω
- Ignition ON, verify a test lamp illuminates between B+ circuit terminal 6 and ground.
- If the test lamp does not illuminate and the circuit fuse is good
- Ignition OFF.
- Test for less than 2 Ω in the B+ circuit end to end.
- If 2 Ω or greater, repair the open/high resistance in the circuit.
- If less than 2 Ω, verify the fuse is not open and there is voltage at the fuse.
- If the test lamp does not illuminate and the circuit fuse is open
- Ignition OFF.
- Test for infinite resistance between the B+ circuit terminal 6 and ground.
- If less than infinite resistance, repair the short to ground on the circuit.
- If infinite resistance, replace the K8 blower motor control module.
- If the test lamp illuminates
- Connect a DMM between the control circuit X2 terminal 3 and ground.
- Verify the resistance value is between 10 K Ω and 180 K Ω and there is a noticeable change when moving between the commanded fan speeds.
- If not within the specified range or there is no noticeable change
- Ignition OFF, disconnect the harness connector at the K33 HVAC control module.
- Test for less than 1 V between the control circuit terminal 3 and ground.
- If 1 V or greater, repair the short to voltage on the circuit.
- If less than 1 V
- Test for infinite resistance between the control circuit and ground.
- If less than infinite resistance, repair the short to ground on the circuit.
- If infinite resistance
- Test for less than 2 Ω in the control circuit end to end.
- If 2 Ω or greater, repair the open/high resistance in the circuit.
- If less than 2 Ω, replace the K33 HVAC control module.
- If within the specified range and there is a noticeable change
- Disconnect the X1 harness connector at the K8 blower motor control module.
- Connect a 30 A fused jumper between the B+ circuit terminal 1 and B+, and a jumper between the ground circuit terminal 2 and ground.
- Verify the blower motor operates.
- If the blower motor does not operate
Replace the M8 blower motor.
- If the blower motor operates
- If the blower motor does not operate
- Replace the K8 blower motor control module