Hybrid Powertrain Control Module Scan Tool Information
The hybrid powertrain control module is a non-serviceable module within the generator control module. The Hybrid Powertrain Control Module Scan Tool Data Parameters list contains hybrid controls-related parameters. The list is arranged in alphabetical order. A given parameter may appear in any one of the data lists, and in some cases may appear more than once, or in more than one data list in order to group certain related parameters together.
Use the Hybrid Powertrain Control Module Scan Tool Data Parameters list only after the following is determined:
- The Diagnostic System Check - Vehicle is completed.
- On-board diagnostics are functioning properly
The scan tool values from a properly running vehicle may be used for comparison with the vehicle you are diagnosing. The Hybrid Powertrain Control Module Scan Tool Data Parameters list represents values that would be seen on a normally running vehicle.
A scan tool that displays faulty data should not be used. The scan tool concern should be reported to the manufacturer. Use of a faulty scan tool can result in misdiagnosis and unnecessary parts replacement.
Only the parameters listed below are referenced in this service manual for use in diagnosis. If all values are within the typical range described below, refer to Symptoms - Hybrid Controls for diagnosis.
| Parameter | System State | Expected Value | Description |
|---|---|---|---|
| Operating Conditions: Ignition ON/Closed Throttle/Park or Neutral/Accessories OFF, Engine On, normal operating temperature, unless otherwise noted | |||
| 5V Reference 1 | Volts | 5V | This parameter displays the voltage of the 5V reference circuit voltage in the Brake Pedal Switch sensor and the High Voltage Interlock Loop of the Starter Generator. |
| 5V Reference 1 Circuit Status | OK/Malfunction | OK | This parameter displays the current status of the 5V reference circuit voltage in the Brake Pedal Switch sensor and the High Voltage Interlock Loop of the Starter Generator |
| 5V Reference 2 Circuit Status | OK/Malfunction | OK | This parameter displays the current status of the 5V reference circuit voltage in the High Voltage Interlock Loop of the Generator Control and Battery Module |
| 5V Reference 3 | Volts | 5V | This parameter displays the voltage of the 5V reference circuit voltage internal to the Generator Control Module. |
| 5V Reference 3 Circuit Status | OK/Malfunction | OK | This parameter displays the current status of the 5V reference circuit voltage internal to the Generator Control Module |
| 14V Power Module Fan Speed | RPM | Varies | This parameter displays the speed of the hybrid battery cooling fan motor. |
| 14V Power Module High Voltage Circuit Current | Amps | Varies | This parameter displays the high voltage circuit current as determined by the 14V power module. The parameter display range is 1638.4 to +1638.35Amps. |
| 14V Power Module Power Loss | Watts | Varies | This parameter displays the difference in power (power loss) between the input power and the output power of the 14V Power Module. The 14V power module converts high voltage to intermediate or low voltage in order to support the various electrical system loads. The power loss is determined based upon High Voltage current and voltage, Low Voltage current and voltage, and Intermediate Voltage current and voltage measurements from the 14V power module internal sensors. |
| 14V Power Module Setpoint | % | Varies | This parameter displays the target output, expressed in percent, the 14V power module will try to maintain while operating the system. The 14V power module converts high voltage to intermediate or low voltage in order to support the various electrical system loads. |
| 14V Power Module Setpoint | Volts | 14.5 | This parameter displays the target voltage the 14V power module will try to maintain while operating the system. The 14V power module converts high voltage to intermediate or low voltage in order to support the various electrical system loads. |
| 14V Power Module Status | Normal; Out of Range; Low Power Mode; Shutdown Mode; Default; Unknown | Normal | This parameter displays the control status of the 14V power module as controlled in the hybrid powertrain control module. The 14V power module converts high voltage to intermediate or low voltage in order to support the various electrical system loads. |
| 14V Power Module Temperature Sensor 1 | °C (°F) | Varies | 14V Power Module temperature measured by sensor 1 |
| 14V Power Module Temperature Sensor 2 | °C (°F) | Varies | 14V Power Module temperature measured by sensor 2 |
| Autostart Inhibit Reason Autostart/Autostop Malfunction | Yes/No | No | This parameter displays the status of an Autostart Inhibit due to the following reason: Autostart/Autostop Malfunction. |
| Autostart Inhibit Reason Control Function Active | Yes/No | No | This parameter displays the status of an Autostart Inhibit due to the following reason: control function AutoStop Override. |
| Autostart Inhibit Reason Crank Abort | Yes/No | No | This parameter displays the status of an Autostart Inhibit due to the following reason: Crank Aborted. |
| Autostart Inhibit Reason Driver Exited Vehicle | Yes/No | No | This parameter displays the status of an Autostart Inhibit due to the following reason: Driver Left Vehicle. |
| Autostart Inhibit Reason ECM Malfunction | Yes/No | No | This parameter displays the status of an Autostart Inhibit due to the following reason: ECM System Failure. |
| Autostart Inhibit Reason ECM Request | Yes/No | No | This parameter displays the status of an Autostart Inhibit due to the following reason: ECM Request. |
| Autostart Inhibit Reason Engine Coolant Temperature Out of Range | Yes/No | No | This parameter displays the status of an Autostart Inhibit due to the following reason: Engine Coolant Temperature. |
| Autostart Inhibit Reason Hood Ajar | Yes/No | No | This parameter displays the status of an Autostart Inhibit due to the following reason: Hood Open. |
| Autostart Inhibit Reason Hybrid/EV Battery Pack Contactor Open | Yes/No | No | This parameter displays the status of an Autostart Inhibit due to the following reason: HV Battery Contactor Status. |
| Autostart Inhibit Reason Hybrid/EV Battery Pack Power Low | Yes/No | No | This parameter displays the status of an Autostart Inhibit due to the following reason: HV Battery Power Limits. |
| Autostart Inhibit Reason Hybrid/EV Battery Pack State Of Charge Low | Yes/No | No | This parameter displays the status of an Autostart Inhibit due to the following reason: HV Battery State of Charge. |
| Autostart Inhibit Reason Hybrid/EV Battery Pack Voltage Low | Yes/No | No | This parameter displays the status of an Autostart Inhibit due to the following reason: HV Battery Module Voltage. |
| Autostart Inhibit Reason Hybrid/EV Power Conditions | Yes/No | No | This parameter displays the status of an Autostart Inhibit due to the following reason: Hybrid Power Conditions. |
| Autostart Inhibit Reason Hybrid/EV Propulsion System Inactive | Yes/No | No | This parameter displays the status of an Autostart Inhibit due to the following reason: HV Propulsion System. |
| Autostart Inhibit Reason Not Commanded | Yes/No | No | This parameter displays the status of an Autostart Inhibit due to the following reason: Start Not Commanded. |
| Autostart Inhibit Reason Run/Crank Not Active | Yes/No | No | This parameter displays the status of an Autostart Inhibit due to the following reason: Run/Crank Not Active. |
| Autostart Inhibit Reason System Malfunction | Yes/No | No | This parameter displays the status of an Autostart Inhibit due to the following reason: Hybrid System Failure. |
| Autostart Inhibit Reason Transmission Range | Yes/No | No | This parameter displays the status of an Autostart Inhibit due to the following reason: Transmission Range. |
| Autostart Reason A/C Request | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: AC System active. |
| Autostart Reason Acceleration Request | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: Driveability. |
| Autostart Reason Accelerator Pedal Pressed | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: Accelerator Pedal Position. |
| Autostart Reason Auxiliary Transmission Fluid Pump Not Available | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: Auxiliary Transmission Pump. |
| Autostart Reason Brake Booster Weak Vacuum | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: Brake Vacuum Pressure. |
| Autostart Reason Brake Pedal Released | Yes/No | Yes | This parameter displays the status of an Autostart due to the following reason: Brake Pedal Position. |
| Autostart Reason Clutch Pedal Applied | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: Clutch Pedal Pressed. |
| Autostart Reason Control Function Active | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: control function AutoStart Override. |
| Autostart Reason Drive Motor Inverter Temperature High | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: Electric Motor Inverter Temperature. |
| Autostart Reason Drive Motor Temperature High | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: Electric Motor Temperature. |
| Autostart Reason Driver Exited the Vehicle | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: The driver has exited the vehicle. |
| Autostart Reason DTC Present | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: DTC is present. |
| Autostart Reason ECM Request | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: ECM Request. |
| Autostart Reason Engine Coolant Temperature Out of Range | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: Engine Coolant Temperature. |
| Autostart Reason Hood Ajar | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: Hood Open. |
| Autostart Reason Hybrid/EV Battery Module Voltage Low | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: HV Battery Module Voltage |
| Autostart Reason Hybrid/EV Battery Pack Power Low | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: HV Battery Power Limits. |
| Autostart Reason Hybrid/EV Battery Pack State of Charge Low | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: HV Battery State of Charge. |
| Autostart Reason Hybrid/EV Battery Pack Temperature | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: HV Battery Pack Temperature. |
| Autostart Reason Hybrid/EV Battery Pack Voltage Low | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: HV Battery Pack Voltage Level. |
| Autostart Reason Hybrid/EV Propulsion System Inactive | Yes/No | Yes | This parameter displays the status of an Autostart due to the following reason: HV Propulsion System. |
| Autostart Reason Ignition Switch Start | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: Key Forced AutoStart Request. |
| Autostart Reason Inclination | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: Vehicle Grade. |
| Autostart Reason Invalid Data Received | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: Data Validity. |
| Autostart Reason Low-Voltage Battery Discharge Current High | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: 12V Battery Discharge Current. |
| Autostart Reason Low-Voltage Battery State of Charge Low | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: 12V Battery SOC. |
| Autostart Reason Low-Voltage Battery State of Function Low | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: 12V Battery SOF Voltage. |
| Autostart Reason Low-Voltage Battery State of Health Low | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: 12V Battery SOH. |
| Autostart Reason Low-Voltage Battery Voltage Low | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: 12V Battery Voltage. |
| Autostart Reason Maximum Autostop Time Exceeded | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: Max AutoStop Time. |
| Autostart Reason Minimum Engine Run Time Not Met | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: Minimum Run Time Not Met. |
| Autostart Reason Reduced Engine Power Active | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: Reduced Power. |
| Autostart Reason Remote Vehicle Start Request | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: Remote Start. |
| Autostart Reason Stop/Start Select Switch | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: Stop/Start Select Switch. |
| Autostart Reason System Malfunction | Yes/No | No | This parameter displays the status of an Autostart Inhibit due to the following reason: Hybrid System Failure. |
| Autostart Reason System Optimization | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: System Optimization. |
| Autostart Reason System Voltage Low | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: System Voltage Low. |
| Autostart Reason TCM Demand | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: TCM Override. |
| Autostart Reason Transmission Fluid Temperature Out of Range | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: Transmission Temperature. |
| Autostart Reason Transmission In Reverse | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: Reverse Grade. |
| Autostart Reason Transmission Range | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: Transmission Range. |
| Autostart Reason Vehicle Speed Too High | Yes/No | No | This parameter displays the status of an Autostart due to the following reason: Vehicle Speed Too High. |
| Autostop Disable Reason A/C Request | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: AC System. |
| Autostop Disable Reason Acceleration Request | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: Driveability. |
| Autostop Disable Reason Accelerator Pedal Pressed | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: Accelerator Pedal Position. |
| Autostop Disable Reason Auxiliary Transmission Fluid Pump Not Available | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: Auxiliary Transmission Pump. |
| Autostop Disable Reason Brake Booster Weak Vacuum | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: Brake Vacuum Pressure. |
| Autostop Disable Reason Brake Pedal Released | Yes/No | Yes | This parameter displays the status of an Autostop Disable due to the following reason: Brake Pedal Position. |
| Autostop Disable Reason Control Function Active | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: control function AutoStart Override. |
| Autostop Disable Reason Drive Motor Inverter Temperature High | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: Electric Motor Inverter Temperature. |
| Autostop Disable Reason Drive Motor Temperature High | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: Electric Motor Temperature. |
| Autostart Disable Reason Driver Exited the Vehicle | Yes/No | No | This parameter displays the status of an Autostop due to the following reason: The driver has exited the vehicle. |
| Autostop Disable Reason ECM Request | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: ECM Request. |
| Autostop Disable Reason Engine Coolant Temperature Out Of Range | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: Engine Coolant Temperature. |
| Autostop Disable Reason Engine Speed High | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: Engine Speed. |
| Autostop Disable Reason Generator Load High | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: Maximum Generator Load requested. |
| Autostop Disable Reason Hood Ajar | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: Hood Open. |
| Autostop Disable Reason - Hybrid/EV Battery Module Pack Low | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: HV Battery Pack Voltage. |
| Autostop Disable Reason Hybrid/EV Battery Module Voltage Low | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: HV Battery Module Voltage. |
| Autostop Disable Reason Hybrid/EV Battery Pack Power Low | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: HV Battery Power Limits. |
| Autostop Disable Reason Hybrid/EV Battery Pack State Of Charge Low | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: HV Battery State of Charge |
| Autostop Disable Reason Hybrid/ EV Battery Pack Temperature | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: HV Battery Pack Temperature. |
| Autostop Disable Reason Hybrid/EV Propulsion System Inactive | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: HV Propulsion System. |
| Autostop Disable Reason Idle Boost Mode Active | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: Idle Boost Mode. |
| Autostop Disable Reason Ignition Switch Start | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: Key Forced AutoStart Request. |
| Autostop Disable Reason Intake Manifold Weak Vacuum | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: Intake Manifold Pressure. |
| Autostop Disable Reason Invalid Data Received | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: Data Validity. |
| Autostop Disable Reason Low-Voltage Battery Discharge Current High | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: 12V Battery Discharge Current. |
| Autostop Disable Reason Low-Voltage Battery State of Charge Low | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: 12V Battery SOC. |
| Autostop Disable Reason Low-Voltage Battery State of Function Low | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: 12V Battery SOF Voltage. |
| Autostop Disable Reason Low-Voltage Battery State of Health Low | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: 12V Battery SOH. |
| Autostop Disable Reason Low-Voltage Battery Temperature Out of Range | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: 12V Battery Temperature. |
| Autostop Disable Reason Low-Voltage Battery Voltage Low | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: 12V Battery Voltage. |
| Autostop Disable Reason Maximum Vehicle Stop Time Exceeded | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: Too Much Time Since Vehicle Stop. |
| Autostop Disable Reason Minimum Engine Run Time Not Met | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: Minimum Run Time Not Met. |
| Autostop Disable Reason Reduced Engine Power Active | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: Reduced Power. |
| Autostop Disable Reason Remote Vehicle Start Request | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: Remote Start. |
| Autostop Disable Reason Run/Crank Not Active | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: Run/Crank Not Active. |
| Autostop Disable Reason Starter System Malfunction | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: Starting System. |
| Autostop Disable Reason Stop/Start Select Switch | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: Autostop Disable Switch. |
| Autostop Disable Reason System Malfunction | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: System Fault. |
| Autostop Disable Reason System Optimization | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: System Optimization. |
| Autostop Disable Reason System Voltage Low | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: System Voltage Low. |
| Autostop Disable Reason TCM Request | Yes/No | Yes | This parameter displays the status of an Autostop Disable due to the following reason: TCM Override. |
| Autostop Disable Reason Transmission Fluid Temperature Out Of Range | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: Transmission Temperature. |
| Autostop Disable Reason Transmission In Reverse | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: Reverse Grade. |
| Autostop Disable Reason Transmission Range | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: Transmission Range. |
| Autostop Disable Reason Vehicle Inclination | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: Vehicle Grade. |
| Autostop Disable Reason Vehicle Speed Threshold Not Reached | Yes/No | Yes | This parameter displays the status of an Autostop Disable due to the following reason: Vehicle Speed Threshold Not Reached. |
| Autostop Disable Reason Vehicle Speed Too High | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: Vehicle Speed Too High. |
| Autostop Disable Reason Wheel Slip Detected | Yes/No | No | This parameter displays the status of an Autostop Disable due to the following reason: Wheel Slip. |
| Auxiliary Transmission Fluid Pump Relay Control Circuit High Voltage Test Status | Failed, Indeterminate, Passed | This parameter displays the state of the control circuit for the auxiliary transmission fluid pump relay control circuit. | |
| Auxiliary Transmission Fluid Pump Relay Control Circuit Low Voltage Test Status | Failed, Indeterminate, Passed | This parameter displays the state of the control circuit for the auxiliary transmission fluid pump relay control circuit. | |
| Auxiliary Transmission Fluid Pump Relay Control Circuit Open Test Status | Failed, Indeterminate, Passed | This parameter displays the state of the control circuit for the auxiliary transmission fluid pump relay control circuit. | |
| Auxiliary Transmission Pump Relay Command | Off/On | Off | This parameter displays the state of the control circuit for the auxiliary transmission fluid pump relay control circuit. |
| Brake Pedal Position Circuit Signal | Released/Applied | Released | This parameter displays that the brake pedal apply input to the controller indicates that the brake is applied. |
| Brake Pedal Position Sensor Learned Released Position Switch | Yes/No | Yes | This parameter displays that the brake pedal fully released position has been successfully learned. |
| Brake Pedal Position Sensor Signal | Released/Applied | Released | This parameter displays the status of the application of the brake pedal switch input to the controller. |
| Calculated Throttle Position | % | 0 | This parameter displays the accelerator effective position, which represents the drivers intended request for torque or acceleration. It is determined from the maximum of the driver requests to open the throttle (e.g., accelerator pedal, cruise control, PTO, etc.) and is normalized to 0 to 100%, where 0% represents an idle or coast request and 100% represents a request for wide open throttle(WOT). It is the primary indication of accelerator position/throttle position used by transmission control algorithms and, thus, is often referred to as transmission throttle position. In the event that the engine is operating in a forced idle mode due to an accelerator pedal position fault, the accelerator effective position will have a value of 0%, corresponding to an idle request. |
| Contactor Open Reason History 1 | None; Normal Function; DTC Present; Control Function Active Invalid; | Normal Function | This parameter displays one of the last eight reasons that hybrid powertrain control module has either opened the high voltage contactor or prevented the high voltage contactor from closing. |
| Contactor Open Reason History 2 | None; Normal Function; DTC Present; Control Function Active Invalid; | This parameter displays one of the last eight reasons that hybrid powertrain control module has either opened the high voltage contactor or prevented the high voltage contactor from closing. | |
| Contactor Open Reason History 3 | None; Normal Function; DTC Present; Control Function Active Invalid; | This parameter displays one of the last eight reasons that hybrid powertrain control module has either opened the high voltage contactor or prevented the high voltage contactor from closing. | |
| Contactor Open Reason History 4 | None; Normal Function; DTC Present; Control Function Active Invalid; | This parameter displays one of the last eight reasons that hybrid powertrain control module has either opened the high voltage contactor or prevented the high voltage contactor from closing. | |
| Contactor Open Reason History 5 | None; Normal Function; DTC Present; Control Function Active Invalid; | This parameter displays one of the last eight reasons that hybrid powertrain control module has either opened the high voltage contactor or prevented the high voltage contactor from closing. | |
| Contactor Open Reason History 6 | None; Normal Function; DTC Present; Control Function Active Invalid; | This parameter displays one of the last eight reasons that hybrid powertrain control module has either opened the high voltage contactor or prevented the high voltage contactor from closing. | |
| Contactor Open Reason History 7 | None; Normal Function; DTC Present; Control Function Active Invalid; | This parameter displays one of the last eight reasons that hybrid powertrain control module has either opened the high voltage contactor or prevented the high voltage contactor from closing. | |
| Contactor Open Reason History 8 | None; Normal Function; DTC Present; Control Function Active Invalid; | This parameter displays one of the last eight reasons that hybrid powertrain control module has either opened the high voltage contactor or prevented the high voltage contactor from closing. | |
| Crank Abort | Active/Inactive | Inactive | This parameter displays the status of the internal combustion engine crank request of the ECM. The hybrid control module monitors the ECM for this data in order to determine whether to enable or disable ICE cranking. |
| Crank Request | Yes/No | No | This parameter displays the status of the internal combustion engine(ICE) crank request of the ECM. The hybrid control module(HCM) monitors the ECM for this data in order to determine whether to enable or disable ICE cranking. |
| Distance with MIL On | km/miles | Varies | This parameter displays the distance With Malfunction Indicator Lamp On. |
| Drive Motor Belt Maximum Detected Slip | % | Varies | This parameter displays the maximum percent of belt slip detected for the drive motor accessory drive belt. |
| Drive Motor Belt Slip | % | This parameter displays the percent of belt slip detected for the drive motor accessory drive belt. A value of zero indicates that no slip is present. +100% indicates that the starter generator motor is turning and the internal combustion engine(ICE) is not. | |
| Drive Motor Coolant Pump Relay Command | Off/On | On | This parameter displays the Commanded State and the Status of the Drive Motor Coolant Pump Relay. |
| Drive Motor Coolant Pump Relay Control Circuit High Voltage Test Status | OK, Not Run, Malfunction | OK | This parameter displays the Commanded State and the Status of the Drive Motor Coolant Pump Relay. |
| Drive Motor Coolant Pump Relay Control Circuit Low Voltage Test Status | OK, Not Run, Malfunction | This parameter displays the Commanded State and the Status of the Drive Motor Coolant Pump Relay. | |
| Drive Motor Coolant Pump Relay Control Circuit Open Test Status | OK, Not Run, Malfunction | OK | This parameter displays the Commanded State and the Status of the Drive Motor Coolant Pump Relay. |
| Drive Motor Coolant Temperature | °C (°F) | Varies | This parameter displays the temperature of the drive motor coolant. |
| Drive Motor Current | Amps | Varies | This parameter displays the DC current consumed by the starter generator. |
| Drive Motor Inverter Status | Power Stage Inactive; Power Stage Active; Power Stage On: Shutdown Pending; Power Stage On: Active Discharge; Reserved; High Voltage Required | Active | This parameter displays the actual state of the Drive Motor Inverter. |
| Drive Motor Inverter Supply Voltage Circuit | Volts | 114 | This parameter displays the voltage on the DC bus at the drive motor inverter. |
| Drive Motor Speed | RPM | 1800 | This parameter displays the torque commanded by the hybrid powertrain control module to the starter generator. |
| Drive Motor Torque | (lb ft) | Varies | This parameter displays the torque value for the drive motor. |
| Drive Motor Torque Command | (lb ft) | Varies | This parameter displays the commanded torque value requested by the drive motor control module. |
| ECT Sensor | °C (°F) | Varies | This parameter displays the undefaulted engine coolant temperature measured by the sensor. |
| Engine Run Time | Seconds | Varies | This parameter displays the time that the engine has been running. The value of this parameter displays shall freeze if an engine stall occurs and shall be reset. |
| Engine Torque | (lb ft) | Varies | This parameter displays actual engine torque as determined by the ECM. This display is only active when the engine is running. |
| Engine Torque Command | (lb ft) | Varies | This parameter displays commanded engine torque as determined by the ECM. This display is only active when the engine is running. |
| Extended Travel Brake Pedal Position Signal | Active/Inactive | Inactive | This parameter displays the status of the brake pedal travel beyond a moderate/extended travel threshold. |
| Extended Travel Brake Pedal Switch | Active/Inactive | Inactive | This parameter displays the status of the brake pedal travel beyond a moderate/extended travel threshold. |
| High Voltage System Interlock Circuit Status | Unknown, Passed, Failed | Passed | This parameter displays the status of the HV interlock loop. |
| Hood Ajar Switch | Volts | This parameter displays the voltage of the hood ajar switch. | |
| Hood Position | Open/Closed | Closed | This parameter displays the status of the hood latch switch. An autostart will be initiated if the hood switch indicates the hood is open. |
| Hybrid Powertrain Control Module High Voltage Circuit | Volts | 114 | This parameter displays the high voltage circuit voltage as detected by the hybrid powertrain control module which detects voltage in a range from 0-655.35V. |
| Hybrid/EV Battery Multifunction Contactor Command | Open/Closed | Open | This parameter displays the status of the high voltage positive contactor relay. |
| Hybrid/EV Battery Pack Current | Amps | Varies | This parameter displays the actual current flow of the high voltage (115V) electrical system as determined by the Hybrid Powertrain Control Module. The parameter display range is 1638.4 to +1638.35Amps. A negative current value indicates a battery charge while a positive current value indicates a battery discharge. |
| Hybrid/EV Battery Pack Precharge Transistor Command | Open/Closed | Open | This parameter displays the status of the high voltage precharge relay. |
| Hybrid/EV Battery Pack State Of Charge | % | 50 | This parameter displays the hybrid battery State Of Charge as calculated by the hybrid powertrain control module. The parameter display range is 0-100%. |
| Hybrid/EV Battery Pack Voltage | Volts | 114 | This parameter displays the total hybrid battery voltage value. |
| Hybrid/EV Battery Positive Contactor Command | Open/Closed | Closed | This parameter displays the status of the high voltage positive contactor relay (this is the same as multifunction). |
| IAT Sensor | °C (°F) | Varies | This parameter displays the temperature of the internal combustion engine (ICE) intake air as determined by the ECM. The parameter display range is 40°C to +215°C (40°F to +419°F). |
| ICE Backup Start Counter | Counts | Varies | This parameter displays the number of backup starts commanded. (A backup start uses the low voltage starter due to a fault with the high voltage starting system.) This parameter displays value will not reset until a code clear is issued to the controller (either a natural code clear as defined by the diagnostic or a mode $04). If a backup start event has not taken place (either initially or after a code clear), This parameter displays shall default to zero. |
| ICE Start Counter | Counts | Varies | This parameter displays the total number of times the internal combustion engine(ICE) has started over the life of the vehicle. This counter will include both key-crank starts and autostarts. |
| ICE Start Status | No Start Attempted; Hybrid/EV Motor; Starter Motor; Tandem Start; Start Not Complete | No Start Attempted | This parameter displays the status of internal combustion engine (ICE) starting attempts. If an ICE start has completed, this parameter will indicate which starting machine was used for the start. This parameter will also indicate if no ICE start has been attempted or if an ICE start has failed. This parameter information is only valid for the current ignition key cycle. No Start Attempted indicates that no attempt has been made to start the ICE, either via a key crank or an autostart, during the current ignition key cycle. Hybrid/EV Motor indicates that the starter generator was used to start the ICE. Starter Motor indicates that the conventional ICE starter motor was used to start the ICE. Tandem Start indicates that a combination of the starter generator and conventional starter motor was used to start the ICE. Start Not Complete indicates that an ICE start was attempted, but failed. |
| ICE Status | Engine Stalled, Stop, Running, Start, Off, Silent Start, Invalid | Running | This parameter displays the current status of the internal combustion engine (ICE) as determined by the ECM. The hybrid powertrain control module monitors the ECM for this data in order to determine ICE status. |
| Ignition1 Signal | Volts | 14.5 | Run/Crank Voltage |
| Ignition Input Accessory | Active/Inactive | Active | This parameter displays that the accessory hardwire power input to the hybrid powertrain control module. |
| Ignition Input Off/On/Start | Active/Inactive | Active | This parameter displays that the ignition hardwire power input to the hybrid powertrain control module. |
| Low Voltage Circuit Current | Amps | Varies | This parameter displays the amount of current for the 12 volt battery as detected by the 14V power module. |
| Low Voltage Circuit Voltage | Volts | 14.5 | This parameter displays the actual voltage of the low voltage (12V) circuit as detected by the 14V power module. The 14V power module internal sensor detects voltage in a range from 0-25.5V. |
| Maximum Hybrid/EV Battery Module Temperature | °C (°F) | Varies | This parameter displays the temperature of the hybrid battery module with the highest temperature. |
| MIL Command | On/Off | Off | This parameter displays the command status to illuminate the malfunction indicator lamp (MIL) on the instrument cluster. |
| Minimum Hybrid/EV Battery Module Temperature | °C (°F) | Varies | This parameter displays the temperature of the hybrid battery module with the lowest temperature. |
| Minimum Hybrid/EV Battery Module Temperature | °C (°F) | Varies | This parameter displays the temperature of the hybrid battery module with the lowest temperature. |
| On-Board Jump Assist Counter | Counts | Varies | This parameter displays the on-board jump start counter which increments each time an on-board jump start is initiated. |
| On-Board Jump Assist Successful Crank Request Counter | Counts | Varies | This parameter displays the on-board jump start key crank counter which increments each time a successful key crank occurs. |
| On-Board Jump Start Disable Reasons | Not Requested; Key not in Run- Incorrect Power Mode; Faults Present; Counters Exceeded; Jump Start Time Out; High Voltage Battery Status; HV Battery Contactor not Closed; HV Battery Low Discharge Power; Trans Shift Lever Position not in Park; Loss of Communication; Jump Start Max Time Out; Jump Start Inactive Time Out; Crank Assist Timeout | Not Requested | This parameter displays the general operating condition that is inhibiting the on-board jump start feature. |
| On-Board Jump Start Status | Inactive; In Progress; Complete; System Power Mode; Disabled | Inactive | This parameter displays the following statuses of the On-board Jump Start feature:
|
| Power Mode | Off; Accessory; Run; Crank Request | Run | This parameter displays system power mode status as determined by ignition switch inputs to the power mode master. System power mode status should match the ignition switch position. |
| TCC/Cruise Control Brake Pedal Switch | Active/Inactive | This parameter displays that the undebounced/undefaulted state of the redundant discrete brake switch input to the hybrid powertrain control module indicates that the brake is applied. | |
| Torque Delivered Signal | (lb ft) | Varies | This parameter displays the Engine Actual Steady State Torque. |
| Vehicle Speed | km/h (mph) | 0 | This parameter displays the vehicle speed calculated from the transmission output speed. |
| OutputControl | Description |
|---|---|
| 14V Power Module Set Point | This control function is used to override the state of the 14V power module low voltage output. The level of the low voltage output is controlled by the value supplied for Regulation of Low Voltage. |
| Auto Start/Stop |
NOTE:
|
| Auxiliary Transmission Fluid Pump Relay | This control function is used to override the state of the auxiliary transmission fluid pump relay output by turning the relay ON and OFF. |
| Clear Secured High Voltage DTCs |
NOTE:
Perform the high voltage disable procedure and repair or replace damaged high voltage components as specified in the applicable diagnostic prior using this control.
|
| Drive Motor Coolant Pump Relay | This control function is used to override the state of the electric motor A coolant pump relay output by turning the relay ON and OFF. |
| Drive Motor Speed | This control function is used to override the state of electric motor in a hybrid/electric vehicle. The drive motor belt must be removed first in order for this to operate. |
| Hybrid/EV Battery Pack Cooling Fan | This control function is used to override the state of the power pack (hybrid battery) cooling fan. |
| ICE Only Mode | This control function allows the 14V power module to charge the 12volt battery, but disables hybrid functions. Normal Car is defined in which the engine only provides the propulsion to drive the vehicle while the operation of hybrid subsystem is limited to charging the 12V. Disabled features include hybrid deceleration fuel cutoff, hybrid regeneration, and ICE autostop. |
| OnBoard Jump Assist Counter Reset | This control function is used to allow a service technician to reset the Jump Assist parameter counter. |