Home >> Buick >> 2017 >> LaCrosse Base >> Repair and Diagnosis (Single Page) >> Accessories & Equipment >> Communication Devices >> Programming And Setup - All Systems >> Repair Instructions >> Sunroof Control Module Programming and Setup (CF5) >> If the Process is interrupted right at the hard stop:
April 5, 2026: LEMON Manuals is launched! Read the announcement.

If the Process is interrupted right at the hard stop:

The controller needs to see motor movement to initialize but no movement can occur because the process was interrupted when the motor was stalled against the hard stop:

  1. Either disconnect power and or ignition to the drive.
  2. Insert a 4mm hex wrench into the drive assembly and back the motor away from the hard stop (move the glass toward CLOSE) about 2 inches. Repeat if glass can't achieve closed position.
  3. Reconnect power to the drive. Proceed as directed above in, "For An Existing Drive Assembly".