Removal Procedure
Drive Motor Power Inverter Module Cover (3) - Remove - Drive Motor Power Inverter Module Cover Replacement
Drive Motor Power Inverter Module Shield (2) - Remove - Drive Motor Power Inverter Module Shield Replacement
- Disable the high voltage system. High Voltage Disabling
- NOTE:
Cap or plug the coolant hose and the generator control module outlet pipe, so coolant does not contaminate any electrical connectors.
Generator Control Module Coolant Pump Hose (2) @ Generator Control Module (1) - Remove - Generator Control Module Coolant Pump Hose Replacement (LHN)
- NOTE:
Cap or plug the coolant hose and the generator control module outlet pipe, so coolant does not contaminate any electrical connectors.
Generator Control Module Coolant Hose (2) @ Generator Control Module (1) - Remove - Generator Control Module Coolant Hose Replacement (LHN Generator Control Module Coolant Hose to Generator Control Module)
High Voltage Electrical Connector (1) - Disconnect [2x]
- Electrical Connector (2) - Disconnect
- Engine Harness Ground Fastener (3) - Remove
- Engine Harness Ground Terminal (4) - Remove
Battery Positive Junction Block Cable Nut (2) @ Generator Control Module (3) - Remove
- Battery Positive Junction Block Cable (1) - Remove
Generator Control Module Bolt (1) - Remove [2x]
- Generator Control Module Nut (2) - Remove
Engine Control Module Bracket (2) - Reposition away
- Generator Control Module (1) - Remove