Control Solenoid Valve and Transmission Control Module Assembly Input Shaft Speed/Output Shaft Speed Input Test
Special Tools
- EL 35616 GM-Approved Terminal Test Kit
- EL 38522 Variable Signal Generator
For equivalent regional tools, refer to Special Tools .
The purpose of this test is to provide a simulated input/output speed sensor (ISS/OSS) signal to the control solenoid valve assembly ISS/OSS input circuits.
Transmission Input Speed Sensor
- Ignition OFF, disconnect the ISS wiring harness connector X3 (1) from the control solenoid valve assembly.
- Ignition ON, test for 8 - 12 volts at terminal B.
- If not within the specified range, replace the control solenoid valve assembly. Refer to Control Solenoid Valve and Transmission Control Module Assembly Replacement .
- Ignition OFF, using the EL 35616 terminal test kit, connect the EL 38522 variable signal generator red lead to the ISS signal circuit terminal A on the TCM.
- Connect the black lead from the EL 38522 variable signal generator to chassis ground.
- Set the EL 38522 variable signal generator to 5 volts, the frequency to 300 Hz, and the percent duty cycle to 50 or the normal position.
- Ignition ON, verify with a scan tool the Transmission ISS parameter is between 490 - 510 RPM.
- If not between 490 and 310 RPM
Replace the control solenoid valve assembly. Refer to Control Solenoid Valve and Transmission Control Module Assembly Replacement .
- Go to next step: If between 490 and 5110 RPM
- If not between 490 and 310 RPM
- All OK.
If the parameter value is not within the specified range, or a loss of scan tool communication with the TCM is observed, connect the black lead from the EL 38522 variable signal generator to battery ground.
Transmission Output Speed Sensor
- Ignition OFF, disconnect the OSS wiring harness connector X4 (2) from the control solenoid valve assembly.
- Ignition ON, test for 8 - 12 volts at terminal B.
- If not within the specified range, replace the control solenoid valve assembly. Refer to Control Solenoid Valve and Transmission Control Module Assembly Replacement .
- Ignition OFF, using the EL 35616 terminal test kit, connect the EL 38522 variable signal generator red lead to the OSS signal circuit terminal A on the TCM.
- Connect the black lead from the EL 38522 variable signal generator to chassis ground.
- Set the EL 38522 variable signal generator to 5 volts, the frequency to 300 Hz, and the percent duty cycle to 50 or the normal position.
- Ignition ON, verify with a scan tool the Transmission OSS parameter is between 745 - 825 RPM.
- If not between 745 and 825 RPM
Replace the control solenoid valve assembly. Refer to Control Solenoid Valve and Transmission Control Module Assembly Replacement .
- Go to next step: If between 745 and 825 RPM
- If not between 745 and 825 RPM
- All OK.
If the parameter value is not within the specified range, or a loss of scan tool communication with the TCM is observed, connect the black lead from the EL 38522 variable signal generator to battery ground.