Window Switch To Window Motor Harness
- Disconnect harness connector from motor. Insert one end of a jumper wire in switch connector and other end of jumper to motor lead in connector. Using a test lamp, check for current at motor connector. If lamp does not light, switch to motor harness is shorted or has open circuit. Check other terminal using same procedure.