LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Cadillac >> 1998 >> DeVille Base >> Repair and Diagnosis >> Accessories & Equipment >> Memory Modules >> Memory System >> System Testing >> Both Mirrors Do Not Move Manually
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Both Mirrors Do Not Move Manually

NOTE: After repair or component replacement is completed, perform MEMORY SYSTEM CHECK  under TESTING - SYSTEM CHECKS to verify system is operating properly.
  1. Performed MEMORY SYSTEM CHECK  under TESTING - SYSTEM CHECKS. Go to next step.
  2. Using test light, backprobe between outside mirror switch connector terminal "E" (Orange wire) and ground. If test light illuminates, go to next step. If test light does not illuminate, go to step 7).
  3. Using test light, backprobe between outside mirror switch connector terminals "E" (Orange wire) and "D" (Black wire). If test light illuminates, go to next step. If test light does not illuminate, go to step 8).
  4. If both mirrors operate in all directions during memory recall functions, go to next step. If both mirrors do not operate in all directions during memory recall functions, go to step 6).
  5. Replace outside mirror switch. See MIRRORS - POWER article.
  6. Replace Memory Mirror Module (MMM).
  7. Repair open in circuit No. 1740 (Orange wire) between outside mirror switch and splice S505. See WIRING DIAGRAMS  .
  8. Repair open in circuit No. 50 (Black wire) between outside mirror switch and splice S200. See WIRING DIAGRAMS  .