Removal Procedure

  1. Disable the high voltage system. Refer to High Voltage Disabling
  2. Air Cleaner Assembly (1)» Remove - Air Cleaner Assembly Replacement
    Fig 1: Air Cleaner Assembly
    GM4245544Courtesy of GENERAL MOTORS COMPANY
  3. Power Distributor Fuse Block Cover (1)» Remove
    Fig 2: Power Distributor Fuse Block Cover
    GM4248667Courtesy of GENERAL MOTORS COMPANY
  4. Generator Cable Fastener (2)» Remove
    Fig 3: Generator Cable And Fastener
    GM4487155Courtesy of GENERAL MOTORS COMPANY
  5. Generator Cable (1)» Remove
  6. Retainer (1)» Disengage [2x]
    Fig 4: Wiring Harness Retainer
    GM4248671Courtesy of GENERAL MOTORS COMPANY
  7. Engine Wiring Harness (2)» Reposition away
  8. Retainer (1)» Disengage [2x]
    Fig 5: Retainers
    GM4487158Courtesy of GENERAL MOTORS COMPANY
  9. Underbody Front Air Deflector (4)» Remove -Underbody Front Air Deflector Replacement
    Fig 6: Underbody Front Air Deflector
    GM4311446Courtesy of GENERAL MOTORS COMPANY
  10. Retainer (1)» Disengage
    Fig 7: Retainer And Clips
    GM4487162Courtesy of GENERAL MOTORS COMPANY
  11. Retainer Clip (2)» Disengage [2x]
  12. Retainer (1)» Disengage [2x]
    Fig 8: Retainers
    GM4487164Courtesy of GENERAL MOTORS COMPANY
  13. Radiator Inlet Hose (2)» Remove - Radiator Inlet Hose Replacement (LTG without HP9) , Radiator Inlet Hose Replacement (LGW) , Radiator Inlet Hose Replacement (LGX) and/or Radiator Inlet Hose Replacement (LTG with HP9)
    Fig 9: Radiator Inlet Hose
    GM4244690Courtesy of GENERAL MOTORS COMPANY
  14. Retainer (1)» Disengage
    Fig 10: Retainer, Protective Cap, Generator Cable And Fastener
    GM4487166Courtesy of GENERAL MOTORS COMPANY
  15. Protective Cap (3)» Remove
  16. Generator Cable Fastener (2)» Remove
  17. Generator Cable (4)» Remove