Circuit/System Testing
NOTE:
You must perform Circuit/System Verification before Circuit/System Testing.
- Ignition ON.
- Record the value of the Stop/Start Capacitor Control Module Diagnostic Test Abort Counter scan tool parameter.
- Verify the Stop/Start Capacitor Voltage scan tool parameter is 2 V or greater.
- If less than 2V
- Clear the DTC, perform the Stop Start Capacitor Control State of Health Reset.
- Ignition OFF and all vehicle systems OFF.
- Wait a minimum of 3 minutes.
- Ignition ON
- Verify the Stop/Start Capacitor Control Module Diagnostic Test Abort Counter scan tool parameter value is not greater than or equal to the reading in step 2.
- If greater than or equal to the reading in step 2, replace the K176 Stop/Start Capacitor Control Module
- If not greater than or equal to the reading in step 2, all OK
- If greater than or equal to 2 V
- Replace the K176 Stop/Start Capacitor Control Module.