Typical Scan Tool Data
14V Power Module Feedback
| Duty Cycle (+/- 2%) | 14V Power Module Condition Observed | 14V Power Module / System Function |
|---|---|---|
| 100% |
|
Disable |
| 90% | Overtemperature | Disable |
| 70% |
|
Disable |
| 60% | Hot Temperature | Derated: 12V Output limited to <90% of desired |
| 50% | Overtemperature | Derated: 12V Output limited to >90% of desired |
| 30% |
|
Derated: 12V Output < than desired by unknown amount |
| 25% | Approaching Maximum Output Capability: 12V Load > than 95% with temperature normal | 12V vehicle loads may shutdown |
| 20% | Approaching Maximum Output Capability: 12V Load > than 90% with temperature normal | 12V vehicle loads may shutdown |
| 10% | All OK | Normal Operation |
| 0% | 14V Power Module Feedback Circuit Shorted to ground | Disabled |