DTC 35, Data Strobe CKT Shorted To Battery Or CCM INTRNL Open: Notes
Data strobe circuit provides timing signal which causes contents of LCD buffer to display. This occurs after all 160 bits have been clocked into LCD buffer. Data strobe circuit is brought low by CCM for about 80 milliseconds during CCM power-up. CCM takes samples of data strobe circuit during the last 40 milliseconds to ensure circuit is responding to CCM command.
DTC 35 will set when CCM senses high samples on data strobe circuit when samples should be low during CCM power-up.
When DTC 35 is set, SYS will flash. DTC 35 will clear when CCM does not sense high samples on data strobe circuit during CCM power-up.