LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Chevrolet >> 1998 >> Forward Control P12 >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 16 (Starting System) >> Bench Testing >> Solenoid Windings Tests >> Hold-In Windings Test
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Hold-In Windings Test

WARNING: This page is about a different variant/trim than selected.
  1. If solenoid is not removed from starter motor assembly, disconnect field lead from terminal "M" on solenoid and insulate field lead from solenoid motor terminal. Connect an ammeter and switch in series with 12-volt battery and starter solenoid terminal "S" as illustrated. See Figure. Connect a voltmeter between solenoid terminal "S" and ground. Connect a carbon pile across battery.
  2. Turn switch on and quickly adjust carbon pile load until voltage reads as specified. Check ammeter reading. Turn off carbon pile and open switch. On gasoline engines, at 10 volts reading should be 10-20 amps. On diesel engines, at 10 volts reading should be 12-14 amps. If amperage reading is not as specified, replace starter solenoid.