Home >> Chevrolet >> 2000 >> Cavalier L4-2.2L VIN 4 >> Repair and Diagnosis >> Powertrain Management >> Computers and Control Systems >> Testing and Inspection >> Scan Tool Testing and Procedures >> Scan Tool Data, Normal Values and Definitions >> Scan Tool Data Definitions - Powertrain Systems >> HO2S 2
April 5, 2026: LEMON Manuals is launched! Read the announcement.

HO2S 2

Range 0-1132 mV
The rear Heated Oxygen Sensor (HO2S 2) represents the exhaust oxygen output voltage past the catalytic converter. This voltage remains inactive, or the voltage will appear lazy within a range of 100 mV (lean exhaust) and 900 mV (rich exhaust) when the system is operating in a Closed Loop.