Typical Scan Tool Data
IMT VALVE OPEN
| Scan Tool Parameter | Normal Range |
|---|---|
Normal Operating Conditions: The following scan tool parameters listed below produced the same results from the following operating conditions
|
|
| IMT Valve Command | Open |
| IMT Valve Command | OFF |
| IMT Valve Solenoid Circuit Status | Incomplete |
| IMT Valve Position | Open |
| IMT Valve Feedback | 8-12 momentarily during first start-up 15-30% |
IMT VALVE CLOSED
| Scan Tool Parameter | Normal Range |
|---|---|
| Operating Conditions: Vehicle accelerating with moderate throttle (TP sensor above 45 percent) engine speed above 1000 RPM. | |
| IMT Valve Command | Closed |
| IMT Valve Command | ON |
| IMT Valve Solenoid Circuit Status | OK or Incomplete |
| IMT Valve Position | Closed |
| IMT Valve Feedback | 70-90% |