Typical Scan Tool Data
APP Sensor
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
The engine is operating at idle. Parameter Normal Range: APP Sensor 1 0%/1 Volts Parameter Normal Range: APP Sensor 2 0%/0.5 Volts |
|||
| 5-Volt Reference | 0%/0.00 Volts | 0%/0.00 Volts | 0%/4.98 Volts |
| APP Sensor 1 Signal | 0%/0.00 Volts | 0%/0.00 Volts | 0%/4.98 Volts |
| APP Sensor 2 Signal | 0%/0.00 Volts | 0%/0.00 Volts | 0%/4.98 Volts |
| APP Sensor 1 Low Reference | - | 0%/4.98 Volts | - |
| APP Sensor 2 Low Reference | - | 0%/4.98 Volts | - |