Circuit/System Testing
WARNING: This page is about a different car, the 2011 GMC Acadia, 2011 Chevrolet Traverse, and 2011 Buick Enclave. However, it is still accessible from the selected car via links, so may be relevant.
- Ignition OFF, disconnect the harness connector at the A23C liftgate latch assembly.
- Test for less than 30 Ω between the low reference circuit terminal 2 and ground.
- If greater than the specified range, test the low reference circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the K39 liftgate control module.
- Ignition ON, verify the scan tool LGM Latch Pawl Sw parameter is Inactive.
- If not the specified value, test the signal circuit terminal 5 for a short to ground. If the circuit tests normal, replace the K39 liftgate control module.
- Install a 3 A fused jumper wire between the signal circuit terminal 5 and the low reference circuit terminal 2. Verify the scan tool LGM Latch Pawl Sw parameter is Active.
- If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the K39 liftgate control module.
- Verify the scan tool LGM Latch Ratchet Sw. parameter is Inactive.
- If not the specified value, test the signal circuit terminal 6 for a short to ground. If the circuit tests normal, replace the K39 liftgate control module.
- Install a 3 A fused jumper wire between the signal circuit terminal 6 and low reference circuit terminal 2. Verify the scan tool LGM Latch Ratchet Sw. parameter is Active.
- If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the K39 liftgate control module.
- Verify the scan tool LGM Latch Sector Sw. parameter is Inactive.
- If not the specified value, test the signal circuit terminal 4 for a short to ground. If the circuit tests normal, replace the K39 liftgate control module.
- Install a 3 A fused jumper wire between the signal circuit terminal 4 and low reference circuit terminal 2. Verify the scan tool LGM Latch Sector Sw. parameter is Active.
- If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the K39 liftgate control module.
- If all circuits test normal, test or replace the A23C liftgate latch assembly.