Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the FPCM.
- Connect a DMM set on the volt setting, between the enable control circuit terminal 13 and ground.
- Ignition ON, command the ECM fuel pump ON with a scan tool. The DMM reading should be between 11.5-12.5 V.
- If less than the specified range, test the enable control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM.