Installation Procedure
- Install the drive motor power inverter control module (2) and tighten the fasteners (1) to 9 N.m (80 lb in).
- Install the 300-Volt cables with new or un-damaged seals and tighten the fasteners (1) to 9 N.m (80 lb in).
- With new connector housing and fastener seals, install the three-phase cables and tighten the fasteners (1) to 9 N.m (80 lb in).
- Install the high voltage interlock loop connector fasteners (1) and tighten to 6 N.m (53 lb in).
- Connect the coolant pipes to the power inverter module. Refer to Drive Motor Power Inverter Module Cooling Inlet Hose Replacement and. Drive Motor Generator Control Module Radiator Outlet Hose Replacement .
- Fill the cooling system. Refer to Drive Motor Generator Power Inverter Module Cooling System Draining and Filling .
- Install the ground strap fasteners (2) and tighten to 9 N.m (80 lb in).
- Connect the electrical connectors (1).
- Install the power inverter module cover. Refer to Drive Motor Generator Power Inverter Module Cover Replacement .
- Enable the high voltage system. Refer to High Voltage Enabling .
- For control module programming and setup procedures, refer to Control Module References .
CAUTION:
Refer to Fastener Caution
.