Relay Block - I/P Wire Entry
Connector Part Information
- Harness Type: Instrument Panel
- OEM Connector: 12146836
- Service Connector: 12146836
- Description: 30-Way F Metri-Pack 280 Series, Flexlock (BK)
|
Terminal Part Information
- Pins: A4, C7
- Terminated Lead: 13575721
- Release Tool: J-38125-553
- Diagnostic Test Probe: J-35616-4A (PU)
- Terminal/Tray: 12110844/4
- Core/Insulation Crimp: C/A
- Pins: A6, A7, A9, B4, B7, B9, C6, C9
- Terminated Lead: 13575719
- Release Tool: J-38125-553
- Diagnostic Test Probe: J-35616-4A (PU)
- Terminal/Tray: 12110844/4
- Core/Insulation Crimp: E/4
- Pins: B6, D7, D9
- Terminated Lead: 13575721
- Release Tool: J-38125-553
- Diagnostic Test Probe: J-35616-4A (PU)
- Terminal/Tray: 12110844/4
- Core/Insulation Crimp: E/A
- Pins: C4, D4, D6
- Terminated Lead: 13579923
- Release Tool: J-38125-553
- Diagnostic Test Probe: J-35616-4A (PU)
- Terminal/Tray: 12110842/4
- Core/Insulation Crimp: A/B
|
Relay Block - I/P Wire Entry
| Pin |
Wire |
Circuit |
Function |
| A1-A3 |
- |
- |
Not Used |
| A2 |
- |
- |
Not Available |
| A3 |
- |
- |
Not Used |
| A4 |
0.5 RD/WH |
1040 |
Battery Positive Voltage (T79) |
| 0.35 RD/WH |
1040 |
Battery Positive Voltage (T79) |
| A5 |
- |
- |
Not Available |
| A6 |
0.35 L-BU |
187 |
Rear Fog Lamp Switch Signal (T79) |
| A7 |
0.35 RD/WH |
3140 |
Battery Positive Voltage (C05 or CM7) |
| A8 |
- |
- |
Not Available |
| A9 |
0.35 BK |
1550 |
Ground (C05 or CM7) |
| B1-B3 |
- |
- |
Not Used |
| B4 |
0.35 RD/WH |
1040 |
Battery Positive Voltage (T79) |
| B5 |
- |
- |
Not Used |
| B6 |
0.5 OG |
122 |
Rear Fog Lamp Supply Voltage (T79) |
| B7 |
0.35 GY |
2169 |
Convertible Top Relay Cover Release Control (C05 or CM7) |
| B8 |
- |
- |
Not Used |
| B9 |
0.35 PU |
2168 |
Folding Top Lid Latch Supply Voltage (C05 or CM7) |
| C1-C3 |
- |
- |
Not Used |
| C4 |
2 RD/WH |
1440 |
Battery Positive Voltage |
| C5 |
- |
- |
Not Used |
| C6 |
0.35 WH |
93 |
Fuel Door Release Relay Control |
| C7 |
0.5 RD/WH |
3640 |
Battery Positive Voltage (C05 or CM7) |
| 0.5 RD/WH |
3640 |
Battery Positive Voltage (C05 or CM7) |
| C8 |
- |
- |
Not Used |
| C9 |
0.35 L-BU |
1344 |
Trunk Release Relay Control (C05 or CM7) |
| D1 |
- |
- |
Not Used |
| D2 |
- |
- |
Not Available |
| D3 |
- |
- |
Not Used |
| D4 |
2 RD/WH |
1440 |
Battery Positive Voltage |
| D5 |
- |
- |
Not Available |
| D6 |
2 PK |
79 |
Trunk Release Relay Control |
| D7 |
0.5 RD/WH |
3640 |
Battery Positive Voltage (C05 or CM7) |
| D8 |
- |
- |
Not Available |
| D9 |
0.5 L-BU |
383 |
Trunk Release Control (C05 or CM7) |