Circuit/System Testing

WARNING: This page is about a different car, the 2016 GMC Acadia, 2016 Chevrolet Traverse, and 2016 Buick Enclave. However, it is still accessible from the selected car via links, so may be relevant.
  1. Ignition OFF and all vehicle systems OFF, disconnect the harness connector at the M17 Liftgate Motor Assembly. It may take up to 2 minutes for all vehicle systems to power down.
  2. Test for less than 30 Ω between the low reference circuit terminal 2 and ground.
    • If 30 Ω or greater 
    1. Ignition OFF.
    2. Test for less than 2 Ω in the ground circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit.
      • If less than 2 Ω, repair the open/high resistance in the low reference connection.
    • If less than 30 Ω 
  3. Ignition ON.
  4. Verify the scan tool LGM Full Open Switch parameter is Inactive.
    • If not Inactive 
    1. Ignition OFF, disconnect the harness connector at the K39 Liftgate Control Module.
    2. Test for infinite resistance between the signal circuit terminal 1 and ground.
      • If less than infinite resistance, repair the short to ground on the circuit.
      • If infinite resistance, replace the K39 Liftgate Control Module.
    • If Inactive 
  5. Install a 3 A fused jumper wire between the signal circuit terminal 1 and the low reference circuit terminal 2.
  6. Verify the scan tool LGM Full Open Switch parameter is Active.
    • If not Active 
    1. Ignition OFF, remove the 3 A fused jumper wire, disconnect the harness connector at the K39 Liftgate Control Module, ignition ON.
    2. Test for less than 1 V between the signal circuit and ground.
      • If 1 V or greater, repair the short to voltage on the circuit.
      • If less than 1 V
    3. Test for less than 2 Ω in the signal circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit.
      • If less than 2 Ω, replace the K39 Liftgate Control Module.
    • If Active 
  7. Test or replace the M17 Liftgate Motor Assembly.