Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the appropriate door module.
- Ignition ON, test for 9.6-13.6 volts between the B+ circuit terminal 20 and ground.
- If less than the specified range, test the B+ circuit for a an open/high resistance. If the circuit tests normal, replace the door module.
- If the circuit tests normal and the system voltage is less than or greater than the specified range, refer to Charging System Test .