Home >> Chevrolet >> 2015 >> Trax LS, FWD >> Repair and Diagnosis (Single Page) >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> HVAC System - Manual >> Diagnostic Information and Procedures >> DTC B0223, B0233, B023A, or B0408: Recirculate Position Command/Air Flow Control/Main Temperature Control (C67) >> Circuit/System Description
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Circuit/System Description

Stepper motors are used for temperature regulation, air distribution control, and recirculation door control.

With the switches, buttons, and dials on the HVAC controls, air temperature door position, mode door position, and recirculation door position can be selected. The selected values are passed to the HVAC control module via serial data. The HVAC control module supplies a switched 12 V control voltage to the stepper motors and energizes the 4 stepper motor coils with a pulsed ground signal. The stepper motors move the appropriate doors to the requested positions.