Circuit/System Verification
- Verify the scan tool parameters listed below display OK:
- 5V Reference 1 Circuit Status
- 5V Reference 3 Circuit Status
- 5V Reference 4 Circuit Status
- If not OK
Refer to Circuit/System Testing.
- If OK
- Verify the scan tool parameters listed below display 4.8-5.2V:
- 5V Reference 1
- 5V Reference 3
- 5V Reference 4
- If not between 4.8-5.2V
Refer to Circuit/System Testing.
- If between 4.8-5.2V
- All OK.