Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the K111 Fuel Pump Driver Control Module, ignition ON.
- Verify a test lamp illuminates between the ignition circuit terminal 6 and ground.
- If the test lamp does not illuminate and the circuit fuse is good
- Ignition OFF, remove the test lamp.
- Test for less than 2 Ω in the ignition circuit end to end.
- If 2 Ω or greater, repair the open/high resistance in the circuit.
- If less than 2 Ω, verify the fuse is not open and there is voltage at the fuse.
- If the test lamp does not illuminate and the circuit fuse is open
- Ignition OFF, remove the test lamp.
- Test for infinite resistance between the ignition circuit and ground.
- If less than infinite resistance, repair the short to ground on the circuit.
- If infinite resistance, replace the K111 Fuel Pump Driver Control Module.
- If the test lamp illuminates
- Ignition OFF, and all vehicle systems OFF, it may take up to 2 minutes for all vehicle systems to power down.
- Verify a test lamp does not between the ignition circuit terminal 6 and ground.
- If the test lamp illuminates
Repair the short to voltage on the circuit.
- If the test lamp does not illuminate
- If the test lamp illuminates
- Replace the K111 Fuel Pump Driver Control Module.