Circuit/System Testing
NOTE:
- Refer to the GE 41413-A operation manual for detailed instructions in Evaporative Emission System Diagnosis
- Larger volume fuel tanks and/or those with lower fuel levels may require several minutes for the floating indicator to stabilize or produce smoke from a leak.
- Ensure that the underbody temperature of the vehicle and the tester are similar.
- Disconnect the purge tube at the quick connector on the EVAP canister side of the Q12 Evaporative Emission Canister Purge Solenoid Valve and install the CH 48096 .
- Connect the GE 41413-A to the CH 48096 .
- Command the EVAP Purge/Seal function to Not Venting with a scan tool to seal the EVAP system.
- Use the flow meter on the GE 41413-A
, calibrated to 0.51 mm (0.020 in) to determine if there is a leak.
- If a leak is detected
- Use the GE 41413-A to apply smoke to the EVAP system at the purge tube until the leak is located using the GE 41413-SPT
- No leak in the EVAP system
- All OK.