Circuit/System Description
The actuators operate using 5 circuits. A 5-volt reference, low reference, signal circuit and two bi - directional 0 or 12 volt control circuits. The HVAC control module supplies a low reference and 5-volt reference to the potentiometer. The HVAC control module monitors the voltage drop across the potentiometer on the door position signal circuit. As the actuator door changes position the door position signal circuit voltage also changes. The two bi - directional control circuits enable the actuator to operate. Both circuits are set to 0 volts when the HVAC control module detects, from the feedback potentiometer, that the actuator is in the desired position. In order to move the actuator, the HVAC control module switches the appropriate control circuit to 12 volts.
- DTC B0228 is for the recirculate actuator
- DTC B0413 is for the left air temperature actuator
- DTC B0423 is for the right air temperature actuator
- DTC B0433 is for the auxiliary air temperature actuator
- DTC B3782 is for the auxiliary mode actuator
- DTC B3779 is for the mode actuator