Control Solenoid Valve and Transmission Control Module Assembly Input Shaft Speed/Output Shaft Speed Input Test
Special Tools
- EL 35616 GM-Approved Terminal Test Kit
- EL 38522 Variable Signal Generator
For equivalent regional tools, refer to Special Tools .
The purpose of this test is to provide a simulated input/output speed sensor (ISS/OSS) signal to the control solenoid valve assembly ISS/OSS input circuits.
Transmission Input Speed Sensor
- Ignition OFF, disconnect the ISS wiring harness connector X3 (1) from the control solenoid valve assembly.
- Ignition ON, test for 8.3 - 9.3 volts at terminal A.
- If not within the specified range, replace the control solenoid valve assembly. Refer to Control Solenoid Valve and Transmission Control Module Assembly Replacement .
- Ignition OFF, using the EL 35616 terminal test kit, connect the EL38522 variable signal generator red lead to the ISS signal circuit terminal B on the TCM.
- Connect the black lead from the EL 38522 variable signal generator to ground.
- Set the EL 38522 variable signal generator to 5 volts, the frequency to 300 Hz, and the percent duty cycle to 50 or the normal position.
- Ignition ON, verify with a scan tool the Transmission ISS parameter is between 495 - 505 RPM.
- If not within the specified range, replace the control solenoid valve assembly. Refer to Control Solenoid Valve and Transmission Control Module Assembly Replacement .
Transmission Output Speed Sensor
- Ignition OFF, disconnect the OSS wiring harness connector X4 (2) from the control solenoid valve assembly.
- Ignition ON, test for 8.3 - 9.3 volts at terminal A.
- If not within the specified range, replace the control solenoid valve assembly. Refer to Control Solenoid Valve and Transmission Control Module Assembly Replacement .
- Ignition OFF, using the EL 35616 terminal test kit, connect the EL 38522 variable signal generator red lead to the OSS signal circuit terminal B on the TCM.
- Connect the black lead from the EL 38522 variable signal generator to ground.
- Set the EL 38522 variable signal generator to 5 volts, the frequency to 300 Hz, and the percent duty cycle to 50 or the normal position.
- Ignition ON, verify with a scan tool the Transmission OSS parameter is between 256 - 266 RPM.
- If not within the specified range, replace the control solenoid valve assembly. Refer to Control Solenoid Valve and Transmission Control Module Assembly Replacement .