K23 Folding Top Control Module: Scan Tool Information
Folding Top Module Scan Tool Data Parameters
| Parameter | Roof Closed Expected Value | Roof Open Expected Value | Description |
|---|---|---|---|
| Operating Conditions: Ignition ON, Vehicle in Park, Folding Top Closed and Luggage Barrier In Place | |||
| Folding Top Luggage Barrier Sensor | On | On | The scan tool displays On or Off. When the luggage barrier is in place, the scan tool will display On. |
| Right Folding Top Header Latched Sensor | On | Off | The scan tool displays On or Off. When the latch is latched, the scan tool will display On. |
| Left Folding Top Header Latched Sensor | On | Off | The scan tool displays On or Off. When the latch is latched, the scan tool will display On. |
| Left Folding Top Header Unlatched Sensor | Off | On | The scan tool displays On or Off. When the latch is unlatched, the scan tool will display On. |
| Right Folding Top Header Unlatched Sensor | On | Off | The scan tool displays On or Off. When the latch motor latch is latched, the scan tool will display On. |
| Folding Top Up Position Sensor | On | Off | The scan tool displays On or Off. When the top is up, the scan tool will display On. |
| Folding Top Down Position Sensor | Off | On | The scan tool displays On or Off. When the top is down, the scan tool will display On. |
| Folding Top Tension Bow Up Sensor | Off | On | The scan tool displays On or Off. When the tension bow is up, the scan tool will display On. |
| Folding Top Tension Bow Down Left Position Sensor | On | Off | The scan tool displays On or Off. When the tension bow is down, the scan tool will display On. |
| Folding Top Tension Bow Down Right Position Sensor | On | Off | The scan tool displays On or Off. When the tension bow is down, the scan tool will display On. |
| Folding Top Stowage Compartment Lid Open Position Sensor | Off | Off | The scan tool displays On or Off. When the stowage compartment lid is open, the scan tool will display On. |
| Folding Top Stowage Compartment Lid Left Closed Position Sensor | On | On | The scan tool displays On or Off. When the stowage compartment lid is closed, the scan tool will display On. |
| Folding Top Stowage Compartment Lid Right Closed Position Sensor | On | On | The scan tool displays On or Off. When the stowage compartment lid is closed, the scan tool will display On. |
| Folding Top Open/Close | Off | Off | The scan tool displays On or Off. When the open/close switch is pressed, the scan tool will display On. |
| Folding Top Pump Motor Overtemperature Protection Counter | 0 | 0 | The scan tool displays the number of Pump Motor Overtemperature Occurrences. |
| Folding Top Valve Overtemperature Protection Counter | Numerical | Numerical | The scan tool displays the number of Valve Overtemperature Occurrences. |
| Total Number of Folding Top Open and Close Cycles | Numerical | Numerical | Total number of folding top open and close cycles. |
| Current Opening Inhibit - Trunk Lid Open | No | No | This parameter indicates whether or not the Folding Top is currently prevented from closing because the Rear Compartment Lid is Open. |
| History Opening Inhibit - Trunk Lid Open | No | No | This parameter indicates whether or not the Top was inhibited from closing some time in past, since its last clear, because the Rear Compartment Lid was Open. |
| Last Inhibited Cycle - Trunk Lid Open Inhibited Open | No | No | This parameter indicates whether or not the last time the Top was inhibited from moving it was prevented from opening because the Rear Compartment Lid was Open. |
| Current Opening Inhibit - Ambient Temperature | No | No | This parameter indicates whether or not the Folding Top is currently prevented from opening because Temperature outside the Vehicle is not in a specified range. |
| History Opening Inhibit - Ambient Temperature | No | No | This parameter indicates whether or not the Top was inhibited from opening some time in past, since its last clear, because the Temperature outside the Vehicle was not in a specified range. |
| Last Inhibited Cycle - Ambient Temperature Inhibited Open | No | No | This parameter indicates whether or not the last time the Top was inhibited from moving it was prevented from opening because Temperature outside the Vehicle was not in a specified range. |
| Current Opening Inhibit - Pump Motor Overtemperature | No | No | This parameter indicates whether or not the Folding Top is currently prevented from opening because of the Folding Top Pump Motor exceeds a specified Temperature. |
| History Opening Inhibit - Pump Motor Overtemperature | No | No | This parameter indicates whether or not the Top was inhibited from opening some time in past, since its last clear, because the the Folding Top Pump Motor exceeded a specified Temperature. |
| Last Inhibited Cycle - Pump Motor Overtemperature Inhibited Open | No | No | This parameter indicates whether or not the last time the Top was inhibited from moving it was prevented from opening because the Folding Top Pump Motor exceeded a specified Temperature. |
| Current Opening Inhibit - Vehicle Speed | No | No | This parameter indicates whether or not the Folding Top is currently prevented from opening because of vehicle speed. |
| History Opening Inhibit - Vehicle Speed | No | No | This parameter indicates whether or not the Top was inhibited from opening some time in past, since its last clear, because of vehicle speed. |
| Last Inhibited Cycle - Vehicle Speed Inhibited Open | No | No | This parameter indicates whether or not the last time the Top was inhibited from moving it was prevented from opening because of vehicle speed. |
| Current Opening Inhibit - High Battery Voltage | No | No | This parameter indicates whether or not the Folding Top is currently prevented from opening because the Battery Voltage measured at its Power Input exceeds a certain value. |
| History Opening Inhibit - High Battery Voltage | No | No | This parameter indicates whether or not the Top was inhibited from opening some time in past, since its last clear, because the Battery Voltage measured at its Power Input exceeded a certain value. |
| Last Inhibited Cycle - High Battery Voltage Inhibited Open | No | No | This parameter indicates whether or not the last time the Top was inhibited from moving it was prevented from opening because the Battery Voltage measured at its Power Input exceeded a certain value. |
| Current Opening Inhibit - Low Battery Voltage | No | No | This parameter indicates whether or not the last time the Top was inhibited from moving it was prevented from opening because the Battery Voltage measured at its Power Input exceeded a certain value. |
| History Opening Inhibit - Low Battery Voltage | No | No | This parameter indicates whether or not the Top was inhibited from opening some time in past, since its last clear, because the the Battery Voltage measured at its Power Input dropped below a specified value. |
| Last Inhibited Cycle - Low Battery Voltage Inhibited Open | No | No | This parameter indicates whether or not the last time the Top was inhibited from moving it was prevented from opening because the Battery Voltage measured at its Power Input dropped below a specified value. |
| Current Closing Inhibit - Trunk Lid Open | No | No | This parameter indicates whether or not the Folding Top is currently prevented from closing because the Rear Compartment Lid is Open. |
| Last Inhibited Cycle - Trunk Lid Open Inhibited Close | No | No | This parameter indicates whether or not the last time the Top was inhibited from moving it was prevented from closing because the Rear Compartment Lid was Open. |
| History Closing Inhibit - Trunk Lid Open | No | No | This parameter indicates whether or not the Top was inhibited from closing some time in past, since its last clear, because the Rear Compartment Lid was Open. |
| Current Closing Inhibit - Ambient Temperature | No | No | This parameter indicates whether or not the Folding Top is currently prevented from closing because Temperature outside the Vehicle is not in a specified range. |
| Last Inhibited Cycle - Ambient Temperature Inhibited Close | No | No | This parameter indicates whether or not the last time the Top was inhibited from moving it was prevented from closing because Temperature outside the Vehicle was not in a specified range. |
| History Closing Inhibit - Ambient Temperature | No | No | This parameter indicates whether or not the Top was inhibited from closing some time in past, since its last clear, because the Temperature outside the Vehicle was not in a specified range. |
Folding Top Module Scan Tool Output Controls
| Output Control | Description |
|---|---|
| Folding Top Pump Motor Relay 1 | The folding top control module will command the pump motor relay to turn on. The pump should operate. |
| Folding Top Pump Motor Relay 2 | The folding top control module will command the pump motor relay to turn on. The pump should operate. |
| Folding Top Solenoid Valve 1 | The folding top control module will command the solenoid to energize. |
| Folding Top Solenoid Valve 2 | The folding top control module will command the solenoid to energize. |
| Folding Top Solenoid Valve 3 | The folding top control module will command the solenoid to energize. |
| Folding Top Open/Close | The folding top control module will command the top to open or close. |