Home >> Chrysler >> 1999 >> Sebring Convertible L4-2.4L VIN X >> Repair and Diagnosis >> Powertrain Management >> Computers and Control Systems >> Relays and Modules - Computers and Control Systems >> Body Control Module >> Testing and Inspection >> Symptom Related Diagnostic Procedures >> Door Ajar >> Open Driver Door (Left Front) Ajar Circuit
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Open Driver Door (Left Front) Ajar Circuit

SYMPTOM LIST
* OPEN DRIVER DOOR (LEFT FRONT) AJAR CIRCUIT

TEST NOTE ALL symptoms listed above are diagnosed using the same tests. The title for the tests will be * OPEN DRIVER DOOR (LEFT FRONT) AJAR CIRCUIT.

POSSIBLE CAUSES
- Left front door ajar switch defective open
- LF door ajar (closed) switch sense circuit open
- Left front door switch ground strap corroded/damaged
- Body 20 way connector (CAV 7) defective
- Body control module defective open input (CAV 7)