General Information
SECURED ACCESS mode is not required to check programmed status of key. If PCM is replaced, unique secret key data must be transferred from SKIM to PCM. This procedure requires SKIM to be placed in SECURED ACCESS mode using 4-digit PIN code.
Sentry Key Immobilizer Module (SKIM) will only remain in secured access mode for 60 seconds. If incorrect unique Personal Identification Number (PIN) is entered 3 times, SKIM will be locked for one hour. To exit lock out mode, turn ignition switch to RUN position continuously for one hour. Ensure all accessories are turned off. Monitor battery state and connect battery charger is necessary. To program smart keys using "customer programming method" requires 2 valid smart keys. See owner's manual.