Home >> Chrysler >> 2003 >> Sebring LXi, 2D Convertible >> Repair and Diagnosis (Single Page) >> Body & Frame >> Body, Cab Control Systems >> Body Diagnostic Procedures - Except Coupe >> System Description And Functional Operation >> Compass/Mini-Trip Computer >> Compass Calibration >> Ambient Temperature Sensor Test
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Ambient Temperature Sensor Test

  1. Turn the ignition OFF.
  2. Disconnect the ATS harness connector.
  3. Measure the resistance of the ATS using the following min/max values:
    • 0°C (32°F) Sensor Resistance = 29.33 - 35.99 Kilohms.
    • 10°C (50°F) Sensor Resistance = 17.99 - 21.81 Kilohms
    • 20°C (68°F) Sensor Resistance = 11.37 - 13.61 Kilohms.
    • 25°C (77°F) Sensor Resistance = 9.12 - 10.86 Kilohms.
    • 30°C (86°F) Sensor Resistance = 7.37 - 8.75 Kilohms.
    • 40°C (104°F) Sensor Resistance = 4.90 - 5.75 Kilohms.

The sensor resistance should read between these min/max values. If the resistance values are not OK, replace the sensor.