Compass Calibration: Notes

The compass module has 2 types of autocalibration; slow-cal and fast-cal. Slow-cal ensures that during normal vehicle operation the compass performs auto-calibration functions to keep the compass sensors in their proper operating range. Whenever the ignition is On and the CMTC receives PCI bus data indicating that engine RPM is greater than zero, auto-calibration is performed continuously.

If the calibration information stored in the compass module memory is not within the normal range after a power-up cycle, the compass will display CAL. The CMTC with enter into the fast-cal mode until calibration is complete.

To enter the compass into Manual Calibration mode, perform the following steps: