Sensor-O2 - 3.8L
| 1 - Item_1xftjhxfdj |
| 2 - Item _2tjsryjy |
NOTE:
When replacing an O2 Sensor, the PCM RAM memory must be cleared, either by disconnecting the PCM C-1 connector or momentarily disconnecting the Battery negative terminal. The NGC learns the characteristics of each O2 heater element and these old values should be cleared when installing a new O2 sensor. The customer may experience driveability issues if this is not performed.
- After removing the sensor, the threads must be cleaned with an 18 mm X 1.5 + 6E tap. If reusing the original sensor, coat the sensor threads with an anti-seize compound such as Loctite 771- 64 or equivalent. New sensors have compound on the threads and do not require an additional coating. Tighten the sensor to 41 N.m (30 ft. lbs.) torque.
- Connect the heated oxygen sensor electrical connector.
- Connect the negative battery cable.