Installation-Non-Pressure System

Fig 1: Identifying Coolant Recovery Container - 2.0/2.4L
GC0058753Courtesy of CHRYSLER LLC
1 - BOLT
2 - RADIATOR NIPPLE
3 - HOSE
4 - COOLANT RECOVERY CONTAINER - NON-PRESSURE
  1. Connect the overflow hose (4) to the radiator nipple (2).
  2. Install container in mounting position and install mounting bolts (1).
  3. Tighten mounting bolts to 10 N.m (89 in. lbs.).
  4. Fill cooling system. See STANDARD PROCEDURE .