LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Chrysler >> 2007 >> Sebring Base, 2.4 K >> Repair and Diagnosis >> Engine Mechanical >> Fuel System >> Fuel Injection >> O2 Sensor >> Installation >> Sensor-Oxygen 1/2 - 2.0/2.4L
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Sensor-Oxygen 1/2 - 2.0/2.4L

Fig 1: Identifying Oxygen Sensor 1.8/2.0L
GC0055487Courtesy of CHRYSLER LLC
Fig 2: View Of Oxygen Sensor 2.4L
GC0055488Courtesy of CHRYSLER LLC

The downstream heated oxygen sensor threads into the exhaust pipe behind the catalytic converter.

  1. After removing the sensor, the exhaust manifold threads must be cleaned with an 18 mm X 1.5 + 6E tap. If reusing the original sensor, coat the sensor threads with an anti-seize compound such as Loctite® 771-64 or equivalent. New sensors have compound on the threads and do not require an additional coating. Tighten the sensor to 41 N.m (30 ft. lbs.).
  2. Install sensor using an oxygen sensor crow foot wrench such as Snap-On tool YA8875 or equivalent.
  3. Connect sensor electrical harness to clips along body.
  4. Connect electrical connector to sensor.
  5. Lower vehicle.
  6. Install the negative battery cable.