Sensor-Oxygen 1/2,2/1 - 2.7L
The O2S are located at the outlet ends of the catalytic converter.
- After removing the sensor, the exhaust manifold threads must be cleaned with an 18 mm X 1.5 + 6E tap. If reusing the original sensor, coat the sensor threads with an anti-seize compound such as Loctite 771-64 or equivalent. New sensors have compound on the threads and do not require an additional coating. Tighten the sensor to 41 N.m (30 ft. lbs.).
- Install the O2S. Tighten to 28 N.m (20 ft. lbs.).
- Connect the O2S wire connector.