Set Condition
The Powertrain Control Module (PCM) detects an open on the (K89) O2 Sensor 1/1 Positive Current Control circuit. After the first fault is detected the sensor is shutdown and re-initialized which takes 9 seconds after which the test is repeated. A fault is set after the monitor runs and fails for 7 counts.