Linkage Operation

  1. Ensure that engine is at normal operating temperature. Remove air cleaner. Depress throttle lever to the 1/4 open position. Rotate choke plate to fully closed position.
  2. Release choke plate. Choke plate should fully open. If binding exists, check for worn, damaged or dirty choke linkage. Repair as necessary.