Establishing Continuous Memory Codes

  1. To ensure proper diagnosis of continuous memory codes, PREPARATION  , EQUIPMENT HOOK-UP, KOEO SELF-TEST, TIMING CHECK, and KOER SELF-TEST must be successfully completed. If both KOEO and KOER SELF-TEST display code 11 (Pass), go to CLEARING CONTINUOUS MEMORY CODES.
  2. If not, return to PREPARATION step and make the necessary repairs indicated in KOEO and ENGINE RUNNING SELF-TEST before going to CLEARING CONTINUOUS MEMORY CODES.