September 30: LEMON manuals is back up on a temporary server! Slowness is possible
Test J: Driver Door Module Does Not Respond
- Disconnect in-line connector C3. Using an ohmmeter, measure the resistance between driver door module connector terminal No. 1 (Light Blue/White wire) and in-line connector terminal No. 4. Is the resistance less than 5 ohms? If yes, go to next step. If no, service Light Blue/White wire. Restore connections and run the Data Link Diagnostic Test. See DATA LINK DIAGNOSTICS
under SELF-DIAGNOSTIC SYSTEM.
- With driver door module connector C2 disconnected, inspect terminal No. 4 and the wire connection to the terminal. Is terminal No. 4 and wire connection okay? If yes, go to next step. If no, service the connector. Restore connections and run the Data Link Diagnostic Test. See DATA LINK DIAGNOSTICS
under SELF-DIAGNOSTIC SYSTEM.
- With driver door module connector C2 disconnected, inspect the module terminal. Is the terminal connection okay? If yes, replace driver door module. See 1996 ACCESSORIES & EQUIPMENT FORD MOTOR CO.-POWER DOOR LOCKS (TOWN CAR)
or 1996 ACCESSORIES & EQUIPMENT FORD MOTOR CO.-POWER DOOR LOCKS (CROWN VICTORIA & GRAND MARQUIS)
articles in ACCESSORIES & EQUIPMENT. Restore connections and run Data Link Diagnostic Test. If yes, service the terminal. Restore connections and run the Data Link Diagnostic Test. See DATA LINK DIAGNOSTICS
under SELF-DIAGNOSTIC SYSTEM.