Deviations From Standard Gasoline Implementation of OBD
- Readiness (all monitors complete) is based on diagnostics for the following 6.0L diesel engine systems:
- Comprehensive component monitor (CCM)
- Misfire detection monitor
- EGR monitor
The glow plug monitor is part of the comprehensive component monitor.
Readiness is based on every OBD (component) having run sufficiently to have found a fault without regard to whether or not a fault exists.
- The OBD drive cycle provided in DIAGNOSTIC METHODS - 6.0L DIESEL is used to clear a P1000 code. The diesel system differs substantially from the gasoline system.
- The command to clear DTCs ONLY clears P1000 if all drive cycle testing has been satisfied. All other detected DTCs are cleared with a CLEAR code command from the diagnostic tool if the fault that caused the DTC is no longer present.